    Detail produk:

    Tempat asal: CINA
    Nama merek: AI
    Sertifikasi: ISO
    Nomor model: A91

    Syarat-syarat pembayaran & pengiriman:

    Kuantitas min Order: 1 set
    Harga: Bisa dinegosiasikan
    Kemasan rincian: Papan keras
    Waktu pengiriman: 20 hari
    Syarat-syarat pembayaran: L/C, T/T, Western Union
    Menyediakan kemampuan: 20 set per bulan
    Hubungi sekarang
    Detil Deskripsi produk
    Standar Uji: ASTM UOP960 Aplikasi: Mengukur Jejak Hidrokarbon Beroksigen dalam Aliran Hidrokarbon Cair
    Metode pengujian: GC Jaminan: 1 tahun
    Catu Daya: AC220V ± 10% 50Hz kata kunci: Kromatagraf Gas UOP960

     

    UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC

    UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC

     

    Flow chart of Measuring Trace Oxygenated Hydrocarbons in Naphtha

     

    2 Configuration

    Item CAT NO. DESCRIPTION QTY
    1 G2091A A91 Plus CG 1
    2 G2011B Software 1
    3 1790M Start-up kit A(including sample injection port))  
    4 #210 FID 2
    5 #120 SISL Capillary Injection Port (0~100 psi) 1
    6 PN5.132.002 One way PCM Pressure Control Module 1
    7 #513 Three automatic valves,with valve box heating and pipeline 1
    8 #561 Six way rotor valve 2
    9 #450 Independent heating column(at the back of FID detector) 1
    10 #515 Side Valve Box 1
    11 #542 Four way liquid injection valve(1.0ul volume,75C and 1000 psi max) 1
    12 #360 Liquid injection valve back pressure damping system assembly 1
    13 ECM.7.342.001 2um stainless steel gas filter 1
    14 #610 Sample ring(0.5mL) 1
    15 PN5.150.006 Deoxidation trap 1
    16 PN5.150.004 Dewatering trap 1
    17 PN5.150.005 Dealkylation trap 1
    18 Pipeline Capillary column 1m*0.53 1
    19 Column 1 20m*530um ID*5um MXT-1,Restek Cat.No.71812 1
    20 Column 2 10m*530 u ID*10 uLowox 1
    21 Column 3 30m*0.53 1
    22 Computer Lenovo 1

     