Rumah ProdukPeralatan Pengujian Produk Minyak Bumi

Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃

Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃

    • Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃
    • Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃
    • Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃
    • Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃
  • Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃

    Detail produk:

    Tempat asal: CINA
    Nama merek: AI
    Sertifikasi: ISO
    Nomor model: RECC-I

    Syarat-syarat pembayaran & pengiriman:

    Kuantitas min Order: 1 set
    Harga: Bisa dinegosiasikan
    Kemasan rincian: Kasus Kayu Lapis
    Waktu pengiriman: 15 hari
    Syarat-syarat pembayaran: L/C, T/T, Western Union
    Menyediakan kemampuan: 200 set per bulan
    Hubungi sekarang
    Detil Deskripsi produk
    Standar: ISO1523 dan ISO3679 Metode pengujian: Piala Tertutup Ekuilibrium Cepat
    Kisaran Pengukuran Titik Nyala: -30℃~50℃ Menampilkan: LCD
    Catu Daya: AC220V, 50Hz Konsumsi daya maksimum: 300W
    Jaminan: 1 tahun Operasi: Otomatis

    Rapid Equilibrium Closed Cup Flash Point Test Instrument

    Rapid Equilibrium Closed Cup Flash Point Test Instrument -30℃~50℃

     

    Introduction

    This Closed cup flash point test instrument is designed and made as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. It can meet the requirements of rapid determination for closed cup flash point of petroleum products in oil,chemical, varnish, paint, railway,aviation, electricity, commercial inspection and science research institution.
    This instrument is specially suitable to determine different kinds of colored paints,oil paints, adhesives,solvents and petroleum products which the closed cup flash point is -30℃~50℃.The instrument is also correspond with ISO1523 and ISO3679.

     

    Characteristics

    1.Designed as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. It can realize purpose of testing closed cup flash point rapidly and at low temperature.
    2.This low temperature flash point test instrument adopts semiconductor refrigeration device and external water cooling device.The size is small and cooling rate is rapid.Easy to operate.
    3.Test sample needed is less.2ml for each time(4ml for solid sample and semi-solid sample)
    4.The determination procedure is automatically completed except ignition.Test results can be printed automatically.

     

    Technical specifications

    1.Power supply: AC(220±10%)V, 50Hz
    2.Flash point measuring range: -30℃~50℃
    3. Precision of determination:
    Absolute difference between two determinations is lower than 2℃(same operator)
    Absolute difference between two determinations is lower than 3℃(different operators)
    4. Temperature control precision: ±0.5℃
    5. Igniting device:Electric igniting gun
    6. Cooling mode:Semiconductor(with cold water cycle at external connection)
    7. Maximum power consumption:300W
    8. Ambient temperature:5℃~30℃
    9. Relative humidity:30%~80%
    10. Dimension:370mm×280mm×280mm

     

    Accessories List

    No. Name Unit Qty
    1 RECC-I Low Temperature Closed Cup Flash Point Test Instrumnet Set 1
    2 Fuse Φ5×20 10A Piece 2
    3 Power wire(250V 10A) Piece 1
    4 Printing paper Roll 1
    5 Flexible pipe(inner diameter Φ8) Meter 3
    6 5ml Sample injector Piece 1
     

     