| Tempat asal: | CINA |
| Nama merek: | AI |
| Sertifikasi: | ISO |
| Nomor model: | AIC-2570 |
| Kuantitas min Order: | 1 set Alat Uji Korosi Layanan Simulasi |
|---|---|
| Harga: | Bisa dinegosiasikan |
| Kemasan rincian: | Kotak kayu lapis untuk satu set Alat Uji Korosi Servis Simulasi |
| Waktu pengiriman: | 30 Hari |
| Syarat-syarat pembayaran: | L/C, T/T, Western Union |
| Menyediakan kemampuan: | 20 set per bulan |
| Catu Daya: | AC220V /50Hz | Standar uji: | ASTM D2570, SH/T0088 |
|---|---|---|---|
| Kekuatan total: | 7kw | Rentang aliran: | 0 ~ 95L / mnt |
| Kontrol suhu: | Omron | Kontrol laju aliran: | flowmeter |
| Kisaran kontrol suhu: | suhu normal ~ 88 ºC | Waktu: | Pengatur waktu digital |
| Warna: | Putih | Layanan OEM: | Tersedia |
Introduction
The sample circulates for 1064h at 88 ºC and a certain flow rate in a closed system composed of a reservoir, a water pump, a radiator and rubber pipes. Its corrosion resistance is determined by the weight loss of typical metal test pieces used in the engine cooling system installed in the reservoir and the state surface of the internal surface of each component visually. The performance change of the sample is determined by analyzing the samples taken from the system regularly during the test cycle.
Characteristic
1. The Simulated Service Corrosion Test Apparatus is composed of operation and display, heating control, speed control, pressure control, flow control system and supporting components;
2. Motor: used for coolant circulation drive, linked with water pump;
3. Water pump: provide the circulation flow required by the standard;
4. Condenser: reduce the test pressure to simulate the automobile working condition;
5. Metal test piece: simulate metal corrosion working conditions;
6. Reservoir: provide catalytic effect;
7. Glass tube: observe the cyclic state of the sample
Technical specifications of ASTM D2570 Simulated Service Corrosion Test Apparatus
| 1 | Applicable standards | ASTM D2570, SH/T0088 |
| 2 | Environmental requirements | 20 ºC ~ 25 ºC, humidity < 60% |
| 3 | Fuse | 20A |
| 4 | Temperature control accuracy | ± 3 ºC |
| 5 | Resolution (measurement) | 0.1 ºC |
| 6 | Flow range | 0 ~ 95L / min |
| 7 | Flow control accuracy | ± 5% |
| 8 | Total power | 7KW |
| 9 | Power supply | AC220V 50HZ |
| 10 | Temperature control range | normal temperature ~ 88 ºC |
![]()