| Tempat asal: | CINA |
| Nama merek: | AI |
| Sertifikasi: | ISO |
| Nomor model: | AIC-4780 |
| Kuantitas min Order: | 1 set |
|---|---|
| Harga: | Bisa dinegosiasikan |
| Kemasan rincian: | Alat Ukur Total Sedimen dikemas dalam hardboard |
| Waktu pengiriman: | 20 hari |
| Syarat-syarat pembayaran: | L/C, T/T, Western Union |
| Menyediakan kemampuan: | 20 set per bulan |
| Standar uji: | ASTM D4780,ISO 10307-2,SH/T0701,SH/T0702 | Metode pengujian: | Penuaan dan Filtrasi Panas |
|---|---|---|---|
| Jumlah sampel: | 25g | Rentang pengukuran: | 0,5%(m/m) |
| Tekanan vakum mutlak: | 40Kpa | Bekerja untis: | Dua |
| Ke arah kunci: | Alat Ukur Total Sedimen | Jaminan: | 1 tahun |
ASTM D4780 Total Sediment Measuring Instrument
![]()
Introduction
This Total Sediment Measuring Instrument is used to determine the total sediment in residual fuel oil with a viscosity of less than 55 mm2/s at 100°C and distillate fuel oil blended with residual components. The maximum total sediment of residual fuel oil is 0.5% (m/m), and the maximum total sediment of distillate fuel oil blended with residual components is 0.40% (m/m)..
Structure
1. Aging bath: electric heating oil bath that can keep 100ºC±0.5ºC.
2. Filter element: made of brass, with copper steam coil attached. The filter element is set up above the vacuum flask.
3. Thermometer: sub-immersion type, the immersion line is 50mm~80mm, and the maximum length is 220mm. The thermometer should be able to record temperatures ranging from 95°C to 105°C. The maximum graduation value is 0.5ºC.
4. Oven: The control temperature is 110ºC±1ºC. It can evaporate the solvent, but there is no danger of fire and explosion.
5. Stirring rod: made of glass or polytetrafluoroethylene, about 150mm in length and 3mm in diameter.
6. Glass beaker: 30ml, either with low mouth or cone. 50ml, narrow neck.
7. Weighing bottle: with frosted glass stopper, number, diameter 80mm, height 40mm.
8. Vacuum source: It can provide the specified absolute pressure of 40kPa±2kPa (61.3kPa vacuum degree).
9. Vacuum meter: It can record the specified absolute pressure or vacuum degree.
10. Glass fiber filter paper: nominal aperture 0.0016mm, diameter 47mm.
11. Cooling container: desiccator or other tightly capped container, used for cooling filter paper before weighing. No desiccant is used.
12. Syringe or washing bottle with scale: the minimum capacity is 25ml, and the graduation value is 0.5ml.
13. Tweezers: flat type.
14. Balance: Sensitivity 0.1mg, used for weighing filter paper. Sensitivity 10mg, used for weighing samples.
II.Technical specifications
| 1 | Sample quantity | 25g |
| 2 | Volume of waste flask | 500ml |
| 3 | Measuring range | 0.5%(m/m) |
| 4 | Test units | Two |
| 5 | Absolute vacuum pressure | 40Kpa |
| 6 | Applicable standards | ASTM D4780,ISO 10307-2,SH/T0701,SH/T0702 |
| 7 | Power supply | AC220V 50HZ |