Rumah ProdukPengujian Minyak Mentah, Bahan Bakar, dan Diesel

Automatic Trace Moisture Tester with Coulometric Karl Fischer Titration Method

Automatic Trace Moisture Tester with Coulometric Karl Fischer Titration Method

Automatic Trace Moisture Tester with Coulometric Karl Fischer Titration Method

Detail produk:

Tempat asal: CINA
Nama merek: AI
Sertifikasi: ISO
Nomor model: CKF

Syarat-syarat pembayaran & pengiriman:

Kuantitas min Order: 1 set
Harga: Bisa dinegosiasikan
Kemasan rincian: Papan keras
Waktu pengiriman: 20 hari
Syarat-syarat pembayaran: L/C, T/T, Western Union
Menyediakan kemampuan: 20 set per bulan
Hubungi sekarang
Detil Deskripsi produk
Standar uji: ASTM D6304,ASTM D1744 Metode pengujian: Titrator Koulometri Karl Fisher
Rentang pengukuran: 1ppm-100% Menampilkan: LCD
Ukuran: 320*240*180mm Berat: 6kg
Catu Daya: AC220V±10%/50HZ Jaminan: 1 tahun

 

Automatic Trace Moisture Tester with Coulometric Karl Fischer Titration Method 

 

 

 

Introduction:
This trace moisture tester adopts Karl Fischer Coulometric method. It owns advantages of high testing accuracy, good repeatability, low testing cost etc. It is used to accurately test trace water content in various liquid, solid and gases. And it is widely applied to petroleum, chemical engineering, pharmacy, electricity, scientific research, education department and so on.


Features:
1. Intelligent Determination is guaranteed by CKF Trace water content tester.
2. Powerful new-generation processor; dual-CPU design.
3. Dual power channels separate electrolytic electrode and measuring electrode; automatically removing all kinds of interference; greatly improving the accuracy of test results.
4. Measuring electrode data directly A / D sample converting; data true value avoids errors caused by analog circuit; results more accurate.
5. CKF trace moisture tester is operated easily.
6. Touch-screen operation; only pressing once then the test will be done automatically and the reported values will automatically display.
7. Background Compensation
8. Large current background compensation. Standby time can be shortened to be less than 10 minutes.
9. Rotating Speed Control
10. Software adjusting stirring speed; selection between 0 to 36.
11. End Point Indication is available for CKF Coulometric Karl Fisher Titrator.
12. Character tips and buzzer
13. Perfect Calculating Function
14. Automatically display, calculate, print ug / ppm / percentages / mg/L / sample name / test date
15. Automatic Date Data Storage
16. Year, month, day, hour, minute, second; automatic storage when power off .


Specifications:

Display LCD
Measuring range 3ug to 200 mg water; Water content range: 1ppm-100%
Resolution 0.01 ug water
Accuracy 10μg-1mg water, ± 0.2%; >1mg water, < ± 0.3% (excluding injection error)
Electrolysis speed max 2.4 mg/min
Electrolytic current 0~430 mA
Ambient temperature 5 ~ 35 ℃
Humidity ≤85%
Power supply AC 220V ± 10%
Dimension 320*240*180mm
Weight about 6kg

 

 

Automatic Trace Moisture Tester with Coulometric Karl Fischer Titration Method

Rincian kontak
Advanced Instruments Co.,Ltd

Kontak Person: Mrs. Sandy

Mengirimkan permintaan Anda secara langsung kepada kami (0 / 3000)