Rumah Produkperalatan pengujian kabel

High Voltage DC Generator Tester Hi-pot Kit with Different Voltage and Current

High Voltage DC Generator Tester Hi-pot Kit with Different Voltage and Current

High Voltage DC Generator Tester Hi-pot Kit with Different Voltage and Current

Detail produk:

Tempat asal: CINA
Nama merek: AI
Sertifikasi: ISO
Nomor model: hvg

Syarat-syarat pembayaran & pengiriman:

Kuantitas min Order: 1 set
Harga: Bisa dinegosiasikan
Kemasan rincian: Kasus Kayu Lapis
Waktu pengiriman: 15 hari
Syarat-syarat pembayaran: T/T, Western Union, L/C
Menyediakan kemampuan: 100000 set per bulan
Hubungi sekarang
Detil Deskripsi produk
Catu Daya: AC220V±10%, 50Hz/60Hz Menampilkan: Digital
Tegangan output: 60KV-400KV Arus keluaran: 2mA-5mA
kata kunci: Generator tegangan tinggi DC Jaminan: 1 tahun

 

High Voltage DC Generator Tester

 

I. Introduction:

Portable DC HV generator is important equipment for DC voltage withstand test and leakage current test of HV electrical equipments, cables, surge arresters in maintain service of electrical production, transmission and consumption departments. The tester has a good performance in stability and protection of faulty specimen breakdown. The separate units of tester make the operator keep enough safe distance with high voltage circuit.

 

 

II. Specifications:

1. High accuracy and reliability: high frequency voltage is boosted by multi-double rectifier. The voltage value is stable and high accuracy. The voltage booster circuit is simple which make the tester is high reliable.

2. Small size and light weight: one person can carry the largest DC HV generator (less than 200kV/2mA). That makes the application of the tester simple and easy.

3. Perfect seal by metal housing make the high voltage booster has strong mechanical performance and high insulation ability.

4. High voltage circuit is protected by metal shell which is connected to earth. That makes the application of the tester is safety enough.

5. Protection circuit avoid the wrong operation of tester. All test should start from zero voltage. If the regulator of voltage is not at zero position the tester will be disenabled when switched on.

6. The leakage current at HV side is measured by digital micro ampere meter. The maximum error of meter can be assured is not more than 1uA.

 

Rated
Output DC
Voltage
(KV)

Rated
Output DC
Current
(mA)

Rated
Output
Power(W)

Voltage
Booster
Height(m)

 Weight(kg)

ZGF-60

60

2

120

0.5

16

 

60

3

180

0.5

 
 

60

10

600

0.5

 

ZGF-120

120

2

240

0.8

20

 

120

5

600

0.8

 
 

120

10

1200

0.8

 

ZGF-200

200

2

400

1.2

26

 

200

5

1000

1.2

 
 

200

10

2000

1.2

 

ZGF-300

300

2

600

1.7

31

 

300

5

1500

1.7

 
 

300

10

3000

1.7

 

Above model are the common requirements. It can also be customized for different voltage and current outputs.

Rincian kontak
Advanced Instruments Co.,Ltd

Kontak Person: Mrs. Sandy

Mengirimkan permintaan Anda secara langsung kepada kami (0 / 3000)